630.941.7600 | [email protected] | valmatic.com 128 4/24 Installation Instructions 40 50 60 70 80 100 200 300 400 500 600 700 800 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 100,000 .03 .04 .05 .06 .07 .08 .1 .2 .3 .4 .5 .6 .7 .8 1 2 7 6 5 4 3 2 1 .8 .7 .6 .5 .4 .3 .2 .1 10 20 30 40 50 60 70 80 100 200 300 400 500 600 700 800 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 10,000 20,000 200,000 .02 .08 .07 4” 3” 4 FEET/SECOND VELOCITY 10 FEET/SECOND VELOCITY 5 FEET/SECOND VELOCITY TYPICAL SIZING RANGE 12 FEET/SECOND VELOCITY 8 FEET/SECOND VELOCITY 6” 8” 10” 12” 14” 16” 18” 20” 24” 30” 36” 42” 54” 48” 60” 66” 72” 4” 3” CUBIC METERS PER HOUR FLOW OF WATER IN GALLONS PER MINUTE HEADLOSS IN FEET OF WATER METERS OF WATER Size 3 4 6 8 10 12 14 16 18 20 24 30 36 42 48 54 60 66 72 Cv 320 570 1,840 2,680 3,770 4,800 7,170 8,600 12,600 15,400 25,600 42,000 72,000 103,000 134,000 170,000 210,000 254,000 302,000 Flow Coefficients Cam-Centric® Plug Valves Cam-Centric® Plug Valves - 100% Port The installation of the valve is important for its proper operation. The valve is capable of flow in either direction but the maximum operating pressure can vary with the location of the seat end (Figure 5). The words “SEAT END” are marked on the valve flange. SUSPENDED SOLIDS SERVICE: For fluids containing suspended solids, special orientations are needed to prevent debris from collecting in the valve. For horizontal installations (Figure 6), the valve should be installed with the flow entering the seat end of the valve and the shaft in a horizontal position with the plug up when open. For vertical installations (Figure 7), the valve must be installed with the seat end up regardless of flow direction. CLEAN SERVICE: For both horizontal and vertical installations, install in the direct pressure orientation (pressure opposite the seat end). AIR AND GAS SERVICE: Install valve in the direct pressure orientation (pressure opposite the seat end). Lubricate plug face with FDA approved silicone grease such as Dow Corning #7 before installation. Gear actuators are required for gas service applications. PUMP DISCHARGE SERVICE: On all horizontal pump discharge applications, the seat end should be towards the pump. BURIED SERVICE: Gear actuators are recommended for buried valves to hold the valve in position and provide multi-turn closure to prevent water hammer. The valve should be installed with the shaft horizontal and the actuator nut directed upwards. The valve box or extension pipe should be installed so that the actuator nut and extension stem turn freely. DIRECT PRESSURE REVERSE PRESSURE SEAT END UP SEAT END SETTLED SOLIDS UP FLOW SEAT END HORIZONTAL SHAFT SETTLED SOLIDS Figure 5. Installation Orientation Figure 6. Horizontal Pipe w/ Solids Figure 7. Vertical Pipe with Solids Headloss Chart